Page created: 17 Aug 2020
|
Page updated: 9 Feb 2021
The following items are known issues in the current version of PingDataGovernance Server.
- Published throughput and latency stats for SCIM, Sideband, and Gateway requests for the Periodic Stats Logger are not recorded until the requests are made and the logger is reset.
- The Policy Administration GUI produces an error when a user attempts to import an exported snapshot that contains references to named value processors.
- Several known issues can occur when you use the Administrative Console with Tomcat 9.0.31. You can resolve these issues by upgrading to Tomcat 9.0.33 or later.
- If you use the create-systemd-script tool to create a forking
systemd service, the service is stopped by the
systemctl stop ping-data-governance.service command. At
that time, you can see the status using the systemctl status
ping-data-governance.service command. That status might contain an
indication of failure:
Active: failed (Result: exit-code)
. This error has to do with the way the service exits. It is harmless.